New to MyHealth?
Manage Your Care From Anywhere.
Access your health information from any device with MyHealth. You can message your clinic, view lab results, schedule an appointment, and pay your bill.
ALREADY HAVE AN ACCESS CODE?
DON'T HAVE AN ACCESS CODE?
NEED MORE DETAILS?
MyHealth for Mobile
Get the iPhone MyHealth app »
Get the Android MyHealth app »
Abstract
Abstract Background: Since 1994 at the authors' institution, approximately 9000 cardiac surgical procedures were performed using activated clotting time (ACT)-monitored heparin anticoagulation for cardiopulmonary bypass and protamine administration calculated from a standard unchanged formula. This formula incorporates physiologic consequences of bypass pump-induced dilutional coagulopathy, platelet dysfunction, and coagulation/fibrinolytic cascade component activation, and thus may overcorrect in a subset of off-pump coronary artery bypass graft (OPCAB) patients who may in fact manifest a relative perioperative hypercoagulability state. This study evaluated a strategy of decreased protamine dosing in OPCAB. Methods: Eighty consecutive OPCAB patients who underwent surgery performed by a single surgeon at a single institution over a 12-month period were retrospectively analyzed. Patients underwent a mean of 2.91 +/- 0.1 OPCAB grafts with full heparinization and 50% of the calculated protamine dose was administered. ACT, partial thromboplastin times, thoracostomy tube outputs, transfusions, and clinical outcomes were assessed. Results: Of 80 patients, 76 (95%) returned to baseline ACT values with 50% protamine dosing. All patients demonstrated intraoperative clinical evidence of hemostasis. Mean 8- and 24-hour thoracostomy tube outputs were 424 +/- 24 mL and 806 +/- 38 mL, respectively. A mean of 1.7 +/- 0.2 packed red blood cell transfusions/patient was administered. There were no transfusions of platelets, fresh frozen plasma, or cryoprecipitate; no reexplorations; and no mortalities. Patients were discharged a mean of 4.4 +/- 0.1 days postoperatively. Conclusion: A standard protamine dosing formula adequate for on-pump cardiac surgical procedures significantly overestimates protamine requirements for OPCAB. Patients treated with decreased protamine do not appear to have adverse outcomes.
View details for PubMedID 14980850